{"id":9456,"date":"2026-11-16T08:18:59","date_gmt":"2026-11-16T08:18:59","guid":{"rendered":"https:\/\/grwinding.com\/?p=9456"},"modified":"2026-11-17T08:42:13","modified_gmt":"2026-11-17T08:42:13","slug":"transformer-winding-machine-operating-procedures","status":"publish","type":"post","link":"https:\/\/grwinding.com\/it\/transformer-winding-machine-operating-procedures\/","title":{"rendered":"Transformer Winding Machine: Operating Procedures"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"9456\" class=\"elementor elementor-9456\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-603b2f1 e-flex e-con-boxed e-con e-parent\" data-id=\"603b2f1\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-418c0a0 elementor-widget elementor-widget-text-editor\" data-id=\"418c0a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Introduction<\/h2><p><img fetchpriority=\"high\" decoding=\"async\" class=\"size-medium wp-image-8553 lazyload\" title=\"\u5fae\u4fe1\u56fe\u7247 20240725111745\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/grwinding.com\/wp-content\/uploads\/2026\/03\/\u5fae\u4fe1\u56fe\u7247_20240725111745-300x169.jpg\" alt=\"\u5fae\u4fe1\u56fe\u7247 20240725111745\" width=\"300\" height=\"169\" \/><noscript><img decoding=\"async\" class=\"size-medium wp-image-8553 lazyload\" title=\"\u5fae\u4fe1\u56fe\u7247 20240725111745\" src=\"https:\/\/grwinding.com\/wp-content\/uploads\/2026\/03\/\u5fae\u4fe1\u56fe\u7247_20240725111745-300x169.jpg\" alt=\"\u5fae\u4fe1\u56fe\u7247 20240725111745\" width=\"300\" height=\"169\" srcset=\"https:\/\/grwinding.com\/wp-content\/uploads\/2026\/03\/\u5fae\u4fe1\u56fe\u7247_20240725111745-300x169.jpg 300w, https:\/\/grwinding.com\/wp-content\/uploads\/2026\/03\/\u5fae\u4fe1\u56fe\u7247_20240725111745-1024x576.jpg 1024w, https:\/\/grwinding.com\/wp-content\/uploads\/2026\/03\/\u5fae\u4fe1\u56fe\u7247_20240725111745-768x432.jpg 768w, https:\/\/grwinding.com\/wp-content\/uploads\/2026\/03\/\u5fae\u4fe1\u56fe\u7247_20240725111745-1536x864.jpg 1536w, https:\/\/grwinding.com\/wp-content\/uploads\/2026\/03\/\u5fae\u4fe1\u56fe\u7247_20240725111745-2048x1152.jpg 2048w, https:\/\/grwinding.com\/wp-content\/uploads\/2026\/03\/\u5fae\u4fe1\u56fe\u7247_20240725111745-18x10.jpg 18w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/noscript><\/p><p>UN <strong>toroidal transformer winding machine<\/strong> winds insulated wire around a ring-shaped magnetic core to form a coil.<\/p><p>Proper setup, wire loading, and parameter configuration help prepare the machine for production.<\/p><p>Guangri offers desktop gear-type, high-speed, and floor-standing <strong>avvolgitrici toroidali<\/strong> for different coil specifications. Explore our <a href=\"https:\/\/grwinding.com\/it\/avvolgitrice-per-trasformatore-toroidale-da-tavolo\/\"><strong>macchine avvolgitrici per trasformatori toroidali da tavolo<\/strong><\/a> to compare available models. This guide covers basic operating procedures and selected machine specifications.<\/p><h2>Pre-Operation Inspection and Machine Setup<\/h2><p><img decoding=\"async\" class=\"size-medium wp-image-7867 lazyload\" title=\"Schema del nucleo toroidale con induttanza e avvolgimento\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/grwinding.com\/wp-content\/uploads\/2025\/07\/Toroidal-core-diagram-with-inductance-and-winding-300x274.webp\" alt=\"Schema del nucleo toroidale con induttanza e avvolgimento\" width=\"300\" height=\"274\" \/><noscript><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-7867 lazyload\" title=\"Schema del nucleo toroidale con induttanza e avvolgimento\" src=\"https:\/\/grwinding.com\/wp-content\/uploads\/2025\/07\/Toroidal-core-diagram-with-inductance-and-winding-300x274.webp\" alt=\"Schema del nucleo toroidale con induttanza e avvolgimento\" width=\"300\" height=\"274\" srcset=\"https:\/\/grwinding.com\/wp-content\/uploads\/2025\/07\/Toroidal-core-diagram-with-inductance-and-winding-300x274.webp 300w, https:\/\/grwinding.com\/wp-content\/uploads\/2025\/07\/Toroidal-core-diagram-with-inductance-and-winding-1024x935.webp 1024w, https:\/\/grwinding.com\/wp-content\/uploads\/2025\/07\/Toroidal-core-diagram-with-inductance-and-winding-768x701.webp 768w, https:\/\/grwinding.com\/wp-content\/uploads\/2025\/07\/Toroidal-core-diagram-with-inductance-and-winding.webp 1122w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/noscript><\/p><p>Before starting the machine, check:<\/p><ul><li><p>Power supply and electrical connections.<\/p><\/li><li><p>Winding mechanisms and moving components.<\/p><\/li><li><p>Wire guides and feeding components.<\/p><\/li><li><p>Wire condition and diameter.<\/p><\/li><li><p>Magnetic core positioning.<\/p><\/li><\/ul><p>Resolve any loose, damaged, or incorrectly positioned components before operation.<\/p><p>Switch on the machine and configure the winding parameters according to the coil drawing. Depending on the model, settings may include:<\/p><ul><li><p>Numero di giri<\/p><\/li><li><p>Winding speed<\/p><\/li><li><p>Direzione dell&#039;avvolgimento<\/p><\/li><\/ul><p>Available functions vary by controller. Follow the operating instructions for the specific model.<\/p><p>For additional reference, the <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/71256\"><strong>IEC 60204-1 standard<\/strong><\/a> outlines general requirements for the electrical equipment of machinery.<\/p><h2>Idle Run and Function Verification<\/h2><p>Perform an idle run before production to check:<\/p><ul><li><p>Whether the machine starts and stops normally.<\/p><\/li><li><p>Whether the winding mechanism moves smoothly.<\/p><\/li><li><p>Whether the turn counter responds correctly.<\/p><\/li><li><p>Whether displayed values match the settings.<\/p><\/li><li><p>Whether abnormal noise or vibration occurs.<\/p><\/li><\/ul><p>If any abnormal condition appears, stop the machine and identify the cause before continuing.<\/p><h2>Wire Loading and Threading<\/h2><p><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-8307 lazyload\" title=\"Avvolgitrice toroidale in funzione\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/grwinding.com\/wp-content\/uploads\/2025\/08\/Toroidal-coil-winding-machine-in-operation-300x225.webp\" alt=\"Avvolgitrice toroidale in funzione\" width=\"300\" height=\"225\" \/><noscript><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-8307 lazyload\" title=\"Avvolgitrice toroidale in funzione\" src=\"https:\/\/grwinding.com\/wp-content\/uploads\/2025\/08\/Toroidal-coil-winding-machine-in-operation-300x225.webp\" alt=\"Avvolgitrice toroidale in funzione\" width=\"300\" height=\"225\" srcset=\"https:\/\/grwinding.com\/wp-content\/uploads\/2025\/08\/Toroidal-coil-winding-machine-in-operation-300x225.webp 300w, https:\/\/grwinding.com\/wp-content\/uploads\/2025\/08\/Toroidal-coil-winding-machine-in-operation-16x12.webp 16w, https:\/\/grwinding.com\/wp-content\/uploads\/2025\/08\/Toroidal-coil-winding-machine-in-operation.webp 500w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/noscript><\/p><p>Select insulated copper wire according to the coil design. Check its diameter and insulation condition before loading.<\/p><p>Thread the wire through the winding mechanism and follow the specified path. Position the magnetic core according to the machine instructions.<\/p><p>Before starting, confirm that:<\/p><ul><li><p>The core is correctly positioned.<\/p><\/li><li><p>The wire passes through the core opening freely.<\/p><\/li><li><p>The wire is not twisted or tangled.<\/p><\/li><li><p>The wire path is clear of moving components.<\/p><\/li><\/ul><p>Correct loading helps prepare the machine for winding.<\/p><h2>Start the Winding Operation<\/h2><p><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-7810 lazyload\" title=\"Avvolgimenti del trasformatore in rame e alluminio: durata e durata\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/grwinding.com\/wp-content\/uploads\/2025\/07\/Copper-vs-aluminum-transformer-windings-about-durability-lifespan-300x170.webp\" alt=\"Avvolgimenti del trasformatore in rame e alluminio: durata e durata\" width=\"300\" height=\"170\" \/><noscript><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-7810 lazyload\" title=\"Avvolgimenti del trasformatore in rame e alluminio: durata e durata\" src=\"https:\/\/grwinding.com\/wp-content\/uploads\/2025\/07\/Copper-vs-aluminum-transformer-windings-about-durability-lifespan-300x170.webp\" alt=\"Avvolgimenti del trasformatore in rame e alluminio: durata e durata\" width=\"300\" height=\"170\" srcset=\"https:\/\/grwinding.com\/wp-content\/uploads\/2025\/07\/Copper-vs-aluminum-transformer-windings-about-durability-lifespan-300x170.webp 300w, https:\/\/grwinding.com\/wp-content\/uploads\/2025\/07\/Copper-vs-aluminum-transformer-windings-about-durability-lifespan-768x434.webp 768w, https:\/\/grwinding.com\/wp-content\/uploads\/2025\/07\/Copper-vs-aluminum-transformer-windings-about-durability-lifespan.webp 830w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/noscript><\/p><p>Start the winding cycle according to the selected model&#8217;s operating procedure.<\/p><p>During production, monitor:<\/p><ul><li><p><strong>Wire placement:<\/strong> Whether the wire follows the required path.<\/p><\/li><li><p><strong>Wire condition:<\/strong> Whether the insulation shows visible damage.<\/p><\/li><li><p><strong>Turn counting:<\/strong> Whether the displayed count operates correctly.<\/p><\/li><li><p><strong>Machine operation:<\/strong> Whether unusual noise or vibration occurs.<\/p><\/li><\/ul><p>If the wire becomes tangled or its position shifts, stop the machine before inspection. Never adjust the wire while moving components are running.<\/p><p>After winding, remove the coil and check it against the required production specifications.<\/p><h2>Guangri Toroidal Transformer Winding Machine Models<\/h2><p>Guangri offers desktop and floor-standing machines for different wire diameters, core dimensions, coil heights, and production requirements.<\/p><h3>1.Desktop Toroidal Transformer Winding Machines<\/h3><p><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-2070 lazyload\" title=\"Avvolgitrice per trasformatore toroidale da tavolo JG 6204 utilizzata per produrre automaticamente diversi prodotti\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/grwinding.com\/wp-content\/uploads\/2024\/05\/JG-6204-Desktop-Toroidal-Transformer-Winding-Machine-used-to-produce-diverse-products-automatically-300x300.webp\" alt=\"Avvolgitrice per trasformatore toroidale da tavolo JG 6204 utilizzata per produrre automaticamente diversi prodotti\" width=\"300\" height=\"300\" \/><noscript><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-2070 lazyload\" title=\"Avvolgitrice per trasformatore toroidale da tavolo JG 6204 utilizzata per produrre automaticamente diversi prodotti\" src=\"https:\/\/grwinding.com\/wp-content\/uploads\/2024\/05\/JG-6204-Desktop-Toroidal-Transformer-Winding-Machine-used-to-produce-diverse-products-automatically-300x300.webp\" alt=\"Avvolgitrice per trasformatore toroidale da tavolo JG 6204 utilizzata per produrre automaticamente diversi prodotti\" width=\"300\" height=\"300\" srcset=\"https:\/\/grwinding.com\/wp-content\/uploads\/2024\/05\/JG-6204-Desktop-Toroidal-Transformer-Winding-Machine-used-to-produce-diverse-products-automatically-300x300.webp 300w, https:\/\/grwinding.com\/wp-content\/uploads\/2024\/05\/JG-6204-Desktop-Toroidal-Transformer-Winding-Machine-used-to-produce-diverse-products-automatically-150x150.webp 150w, https:\/\/grwinding.com\/wp-content\/uploads\/2024\/05\/JG-6204-Desktop-Toroidal-Transformer-Winding-Machine-used-to-produce-diverse-products-automatically-768x768.webp 768w, https:\/\/grwinding.com\/wp-content\/uploads\/2024\/05\/JG-6204-Desktop-Toroidal-Transformer-Winding-Machine-used-to-produce-diverse-products-automatically.webp 1000w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/noscript><\/p><p>Guangri&#8217;s <a href=\"https:\/\/grwinding.com\/it\/avvolgitrice-per-trasformatore-toroidale-da-tavolo\/\"><strong>desktop toroidal winding machine series<\/strong><\/a> includes gear-type medium-speed and high-speed models.<\/p><p><strong>Gear-Type Medium-Speed Series<\/strong><\/p><p>The JG-5204 and JG-6204 are designed for relatively thicker wire applications. Both have a maximum winding speed of 260 rpm and storage capacity for 29 programs.<\/p><table><tbody><tr><th>Technical parameter<\/th><th>JG-5204<\/th><th>JG-6204<\/th><\/tr><tr><td>Diametro del filo<\/td><td>0.70\u20132.00 mm<\/td><td>0.70\u20132.50 mm<\/td><\/tr><tr><td>Maximum winding speed<\/td><td>260 rpm<\/td><td>260 rpm<\/td><\/tr><tr><td>Maximum finished coil OD<\/td><td>60\u2013200 mm<\/td><td>60\u2013200 mm<\/td><\/tr><tr><td>Minimum finished coil ID<\/td><td>40 mm<\/td><td>40 mm<\/td><\/tr><tr><td>Maximum finished coil height<\/td><td>80 mm<\/td><td>100 mm<\/td><\/tr><tr><td>Program capacity<\/td><td>29<\/td><td>29<\/td><\/tr><\/tbody><\/table><p><strong>High-Speed Series<\/strong><\/p><p>The JG-2074 and JG-3074 are designed for wire diameters from 0.20 to 0.70 mm. Both offer a maximum winding speed of 1,000 rpm and storage capacity for 29 programs.<\/p><table><tbody><tr><th>Technical parameter<\/th><th>JG-2074<\/th><th>JG-3074<\/th><\/tr><tr><td>Diametro del filo<\/td><td>0.20\u20130.70 mm<\/td><td>0.20\u20130.70 mm<\/td><\/tr><tr><td>Maximum winding speed<\/td><td>1,000 rpm<\/td><td>1,000 rpm<\/td><\/tr><tr><td>Maximum finished coil OD<\/td><td>60\u2013200 mm<\/td><td>60\u2013200 mm<\/td><\/tr><tr><td>Minimum finished coil ID<\/td><td>35 mm<\/td><td>35 mm<\/td><\/tr><tr><td>Maximum finished coil height<\/td><td>80 mm<\/td><td>100 mm<\/td><\/tr><tr><td>Program capacity<\/td><td>29<\/td><td>29<\/td><\/tr><\/tbody><\/table><p>The four models differ in wire diameter and coil height. Selection should be based on the actual coil design and production requirements.<\/p><h3>2.Floor-Standing Toroidal Winding Machines<\/h3><p>Guangri also offers <a href=\"https:\/\/grwinding.com\/it\/avvolgitrice-per-trasformatori-toroidali-da-pavimento\/\"><strong>floor-standing toroidal winding machines<\/strong><\/a> for larger cores and different production arrangements.<\/p><p><strong>JG-8204 Floor-Standing Toroidal Winding Machine<\/strong><\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-2083 lazyload\" title=\"JG 8204 Avvolgitrice per trasformatore toroidale da pavimento che realizza una tazza\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/grwinding.com\/wp-content\/uploads\/2024\/05\/JG-8204-Floor-Type-Toroidal-Transformer-Winding-Machine-crafting-a-cup-300x300.webp\" alt=\"JG 8204 Avvolgitrice per trasformatore toroidale da pavimento che realizza una tazza\" width=\"300\" height=\"300\" \/><noscript><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-2083 lazyload\" title=\"JG 8204 Avvolgitrice per trasformatore toroidale da pavimento che realizza una tazza\" src=\"https:\/\/grwinding.com\/wp-content\/uploads\/2024\/05\/JG-8204-Floor-Type-Toroidal-Transformer-Winding-Machine-crafting-a-cup-300x300.webp\" alt=\"JG 8204 Avvolgitrice per trasformatore toroidale da pavimento che realizza una tazza\" width=\"300\" height=\"300\" srcset=\"https:\/\/grwinding.com\/wp-content\/uploads\/2024\/05\/JG-8204-Floor-Type-Toroidal-Transformer-Winding-Machine-crafting-a-cup-300x300.webp 300w, https:\/\/grwinding.com\/wp-content\/uploads\/2024\/05\/JG-8204-Floor-Type-Toroidal-Transformer-Winding-Machine-crafting-a-cup-150x150.webp 150w, https:\/\/grwinding.com\/wp-content\/uploads\/2024\/05\/JG-8204-Floor-Type-Toroidal-Transformer-Winding-Machine-crafting-a-cup-768x768.webp 768w, https:\/\/grwinding.com\/wp-content\/uploads\/2024\/05\/JG-8204-Floor-Type-Toroidal-Transformer-Winding-Machine-crafting-a-cup.webp 1000w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/noscript><\/p><p>The JG-8204 is designed for toroidal coil production. Its floor-standing structure provides an alternative to desktop configurations. The suitable setup should be confirmed according to core dimensions, wire diameter, and coil specifications.<\/p><p><strong>JG-8554SR-T300 Avvolgitrice toroidale combinata e nastratrice<\/strong><\/p><p><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-2087 lazyload\" title=\"Macchina automatizzata per la produzione di fili JG8554SR-T300 Avvolgitrice toroidale e nastratrice combinate\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/yH5BAEAAAAALAAAAAABAAEAAAIBRAA7\" data-src=\"https:\/\/grwinding.com\/wp-content\/uploads\/2024\/05\/Automated-wire-making-machine-JG-8554SR-T300-Floor-Type-Toroidal-Transformer-Winding-Machine-300x300.webp\" alt=\"Macchina automatizzata per la produzione di fili JG8554SR-T300 Avvolgitrice toroidale e nastratrice combinate\" width=\"300\" height=\"300\" \/><noscript><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-2087 lazyload\" title=\"Macchina automatizzata per la produzione di fili JG8554SR-T300 Avvolgitrice toroidale e nastratrice combinate\" src=\"https:\/\/grwinding.com\/wp-content\/uploads\/2024\/05\/Automated-wire-making-machine-JG-8554SR-T300-Floor-Type-Toroidal-Transformer-Winding-Machine-300x300.webp\" alt=\"Macchina automatizzata per la produzione di fili JG8554SR-T300 Avvolgitrice toroidale e nastratrice combinate\" width=\"300\" height=\"300\" srcset=\"https:\/\/grwinding.com\/wp-content\/uploads\/2024\/05\/Automated-wire-making-machine-JG-8554SR-T300-Floor-Type-Toroidal-Transformer-Winding-Machine-300x300.webp 300w, https:\/\/grwinding.com\/wp-content\/uploads\/2024\/05\/Automated-wire-making-machine-JG-8554SR-T300-Floor-Type-Toroidal-Transformer-Winding-Machine-150x150.webp 150w, https:\/\/grwinding.com\/wp-content\/uploads\/2024\/05\/Automated-wire-making-machine-JG-8554SR-T300-Floor-Type-Toroidal-Transformer-Winding-Machine-768x768.webp 768w, https:\/\/grwinding.com\/wp-content\/uploads\/2024\/05\/Automated-wire-making-machine-JG-8554SR-T300-Floor-Type-Toroidal-Transformer-Winding-Machine.webp 1000w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/noscript><\/p><p>The JG-8554SR-T300 combines winding and insulation taping through a dual-head design, allowing both operations to be performed simultaneously on large ring-shaped magnetic cores.<\/p><p>It uses a PLC and touchscreen with physical operating buttons. Its control system incorporates servo and stepper motor feedback for closed-loop control.<\/p><p>This model is an option for manufacturers looking to combine winding and insulation taping in one production setup.<\/p><h2>How to Choose Between Desktop and Floor-Standing Machines<\/h2><p>Machine selection depends on wire diameter, core dimensions, finished coil size, and production requirements.<\/p><table><tbody><tr><th>Selection factor<\/th><th>Desktop models<\/th><th>Floor-standing models<\/th><\/tr><tr><td>Esempi<\/td><td>JG-5204, JG-6204, JG-2074, JG-3074<\/td><td>JG-8204, JG-8554SR-T300<\/td><\/tr><tr><td>Configurazione<\/td><td>Compact desktop structure<\/td><td>Floor-standing structure<\/td><\/tr><tr><td>Main considerations<\/td><td>Wire diameter, coil dimensions, speed<\/td><td>Core dimensions, configuration, production process<\/td><\/tr><tr><td>Additional functions<\/td><td>Model-dependent<\/td><td>Winding and taping on JG-8554SR-T300<\/td><\/tr><\/tbody><\/table><p>Maximum winding speed should not be the only selection criterion. Manufacturers should also consider workpiece dimensions and required production functions.<\/p><p>For more information, explore Guangri&#8217;s <a href=\"https:\/\/grwinding.com\/it\/soluzione-tecnologica-di-avvolgimento\/\"><strong>winding technology and solutions<\/strong><\/a>.<\/p><h2>FAQ<\/h2><h3>Q1: What should operators check before starting a toroidal winding machine?<\/h3><p>Check the power supply, mechanical components, wire guides, wire condition, magnetic core, and controller settings. Perform an idle run before production.<\/p><h3>Q2: How do I choose the correct winding speed?<\/h3><p>Speed depends on wire diameter, core dimensions, winding requirements, and machine specifications. The JG-5204 and JG-6204 reach 260 rpm, while the JG-2074 and JG-3074 reach 1,000 rpm. These are maximum model-specific values, not recommended speeds for every coil.<\/p><h3>Q3: What should I do if the wire is not positioned evenly?<\/h3><p>Stop the machine and inspect the wire path, guide components, and workpiece positioning. Check the winding settings against the coil requirements.<\/p><h3>Q4: Can one machine perform both winding and insulation taping?<\/h3><p>Yes. The JG-8554SR-T300 features a dual-head design for simultaneous toroidal winding and insulation taping.<\/p><h3>Q5: How many winding programs can Guangri&#8217;s desktop machines store?<\/h3><p>The JG-5204, JG-6204, JG-2074, and JG-3074 each support 29 stored programs. Other models may have different configurations.<\/p><h2>Conclusione<\/h2><p>Proper setup and operation are important for consistent toroidal coil production.<\/p><p>Guangri provides desktop and floor-standing <strong>avvolgitrici toroidali<\/strong>, including combined winding and taping solutions for different production requirements.<\/p><p><a href=\"https:\/\/grwinding.com\/it\/contattaci\/\"><strong>Contact Guangri<\/strong><\/a> to discuss your winding application and machine requirements.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f2efb2c e-flex e-con-boxed e-con e-parent\" data-id=\"f2efb2c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Explore toroidal transformer winding machine setup, pre-operation checks, idle-run verification, wire loading, and basic winding procedures.<\/p>","protected":false},"author":3,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-9456","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 5.0.4 - aioseo.com -->\n\t<meta name=\"description\" content=\"Explore toroidal transformer winding machine setup, pre-operation checks, idle-run verification, wire loading, and basic winding procedures.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"\u6731\u8fea\"\/>\n\t<meta name=\"google-site-verification\" content=\"IdMijtVH79nVc0eO5aYrAUTBOnWi3sntBAVLjmdRdGg\" \/>\n\t<meta name=\"msvalidate.01\" content=\"138749f494184366b6010b61c2b836c2\" \/>\n\t<meta name=\"yandex-verification\" content=\"6a1ef10daeb9ced8\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/grwinding.com\/it\/transformer-winding-machine-operating-procedures\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 5.0.4\" \/>\n\t\t<meta property=\"og:locale\" content=\"it_IT\" \/>\n\t\t<meta property=\"og:site_name\" content=\"GuangRi -\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Transformer Winding Machine: Operating Procedures 2026\" \/>\n\t\t<meta property=\"og:description\" content=\"Explore toroidal transformer winding machine setup, pre-operation checks, idle-run verification, wire loading, and basic winding procedures.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/grwinding.com\/it\/transformer-winding-machine-operating-procedures\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/grwinding.com\/wp-content\/uploads\/2023\/11\/guangri-winding-machine-logo.webp\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/grwinding.com\/wp-content\/uploads\/2023\/11\/guangri-winding-machine-logo.webp\" \/>\n\t\t<meta property=\"og:image:width\" content=\"2252\" \/>\n\t\t<meta property=\"og:image:height\" content=\"449\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-11-16T08:18:59+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-11-17T08:42:13+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/profile.php?id=100067574001915\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Transformer Winding Machine: Operating Procedures 2026\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Explore toroidal transformer winding machine setup, pre-operation checks, idle-run verification, wire loading, and basic winding procedures.\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/grwinding.com\/wp-content\/uploads\/2023\/11\/guangri-winding-machine-logo.webp\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/transformer-winding-machine-operating-procedures\\\/#blogposting\",\"name\":\"Transformer Winding Machine: Operating Procedures 2026\",\"headline\":\"Transformer Winding Machine: Operating Procedures\",\"author\":{\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/author\\\/judy\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/grwinding.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/\\u5fae\\u4fe1\\u56fe\\u7247_20240725111745.jpg\",\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/transformer-winding-machine-operating-procedures\\\/#articleImage\"},\"datePublished\":\"2026-11-16T08:18:59+00:00\",\"dateModified\":\"2026-11-17T08:42:13+00:00\",\"inLanguage\":\"it-IT\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/transformer-winding-machine-operating-procedures\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/transformer-winding-machine-operating-procedures\\\/#webpage\"},\"articleSection\":\"Uncategorized\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/transformer-winding-machine-operating-procedures\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/#listItem\",\"position\":1,\"name\":\"Guangri\",\"item\":\"https:\\\/\\\/grwinding.com\\\/it\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/category\\\/uncategorized\\\/#listItem\",\"name\":\"Uncategorized\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/category\\\/uncategorized\\\/#listItem\",\"position\":2,\"name\":\"Uncategorized\",\"item\":\"https:\\\/\\\/grwinding.com\\\/it\\\/category\\\/uncategorized\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/transformer-winding-machine-operating-procedures\\\/#listItem\",\"name\":\"Transformer Winding Machine: Operating Procedures\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/#listItem\",\"name\":\"Guangri\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/transformer-winding-machine-operating-procedures\\\/#listItem\",\"position\":3,\"name\":\"Transformer Winding Machine: Operating Procedures\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/category\\\/uncategorized\\\/#listItem\",\"name\":\"Uncategorized\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/#organization\",\"name\":\"GuangRi\",\"url\":\"https:\\\/\\\/grwinding.com\\\/it\\\/\",\"telephone\":\"+8618663696065\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/grwinding.com\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/Guangri-winding-machine-logo-2.webp\",\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/transformer-winding-machine-operating-procedures\\\/#organizationLogo\",\"width\":2032,\"height\":446,\"caption\":\"Guangri winding machine logo\"},\"image\":{\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/transformer-winding-machine-operating-procedures\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/profile.php?id=100067574001915\",\"https:\\\/\\\/www.instagram.com\\\/guangri_electronic_machinery\\\/\",\"https:\\\/\\\/www.tiktok.com\\\/@guangrielectronic?lang=zh-Hans\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UCgjvOcsgZW6E_RB6H87pkrA\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/89337373\\\/admin\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/author\\\/judy\\\/#author\",\"url\":\"https:\\\/\\\/grwinding.com\\\/it\\\/author\\\/judy\\\/\",\"name\":\"\\u6731\\u8fea\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/transformer-winding-machine-operating-procedures\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6df3edc77d960c3f27b8a93aa8be58836a8f13999fceccfb2ad4039d559a72e0?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"\\u6731\\u8fea\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/transformer-winding-machine-operating-procedures\\\/#webpage\",\"url\":\"https:\\\/\\\/grwinding.com\\\/it\\\/transformer-winding-machine-operating-procedures\\\/\",\"name\":\"Transformer Winding Machine: Operating Procedures 2026\",\"description\":\"Explore toroidal transformer winding machine setup, pre-operation checks, idle-run verification, wire loading, and basic winding procedures.\",\"inLanguage\":\"it-IT\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/transformer-winding-machine-operating-procedures\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/author\\\/judy\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/author\\\/judy\\\/#author\"},\"datePublished\":\"2026-11-16T08:18:59+00:00\",\"dateModified\":\"2026-11-17T08:42:13+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/#website\",\"url\":\"https:\\\/\\\/grwinding.com\\\/it\\\/\",\"name\":\"GuangRi\",\"inLanguage\":\"it-IT\",\"publisher\":{\"@id\":\"https:\\\/\\\/grwinding.com\\\/it\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Transformer Winding Machine: Operating Procedures 2026<\/title>\n\n","aioseo_head_json":{"title":"Transformer Winding Machine: Operating Procedures 2026","description":"Explore toroidal transformer winding machine setup, pre-operation checks, idle-run verification, wire loading, and basic winding procedures.","canonical_url":"https:\/\/grwinding.com\/it\/transformer-winding-machine-operating-procedures\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"google-site-verification":"IdMijtVH79nVc0eO5aYrAUTBOnWi3sntBAVLjmdRdGg","msvalidate.01":"138749f494184366b6010b61c2b836c2","yandex-verification":"6a1ef10daeb9ced8","miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/grwinding.com\/it\/transformer-winding-machine-operating-procedures\/#blogposting","name":"Transformer Winding Machine: Operating Procedures 2026","headline":"Transformer Winding Machine: Operating Procedures","author":{"@id":"https:\/\/grwinding.com\/it\/author\/judy\/#author"},"publisher":{"@id":"https:\/\/grwinding.com\/it\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/grwinding.com\/wp-content\/uploads\/2026\/03\/\u5fae\u4fe1\u56fe\u7247_20240725111745.jpg","@id":"https:\/\/grwinding.com\/it\/transformer-winding-machine-operating-procedures\/#articleImage"},"datePublished":"2026-11-16T08:18:59+00:00","dateModified":"2026-11-17T08:42:13+00:00","inLanguage":"it-IT","mainEntityOfPage":{"@id":"https:\/\/grwinding.com\/it\/transformer-winding-machine-operating-procedures\/#webpage"},"isPartOf":{"@id":"https:\/\/grwinding.com\/it\/transformer-winding-machine-operating-procedures\/#webpage"},"articleSection":"Uncategorized"},{"@type":"BreadcrumbList","@id":"https:\/\/grwinding.com\/it\/transformer-winding-machine-operating-procedures\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/grwinding.com\/it\/#listItem","position":1,"name":"Guangri","item":"https:\/\/grwinding.com\/it\/","nextItem":{"@type":"ListItem","@id":"https:\/\/grwinding.com\/it\/category\/uncategorized\/#listItem","name":"Uncategorized"}},{"@type":"ListItem","@id":"https:\/\/grwinding.com\/it\/category\/uncategorized\/#listItem","position":2,"name":"Uncategorized","item":"https:\/\/grwinding.com\/it\/category\/uncategorized\/","nextItem":{"@type":"ListItem","@id":"https:\/\/grwinding.com\/it\/transformer-winding-machine-operating-procedures\/#listItem","name":"Transformer Winding Machine: Operating Procedures"},"previousItem":{"@type":"ListItem","@id":"https:\/\/grwinding.com\/it\/#listItem","name":"Guangri"}},{"@type":"ListItem","@id":"https:\/\/grwinding.com\/it\/transformer-winding-machine-operating-procedures\/#listItem","position":3,"name":"Transformer Winding Machine: Operating Procedures","previousItem":{"@type":"ListItem","@id":"https:\/\/grwinding.com\/it\/category\/uncategorized\/#listItem","name":"Uncategorized"}}]},{"@type":"Organization","@id":"https:\/\/grwinding.com\/it\/#organization","name":"GuangRi","url":"https:\/\/grwinding.com\/it\/","telephone":"+8618663696065","logo":{"@type":"ImageObject","url":"https:\/\/grwinding.com\/wp-content\/uploads\/2023\/11\/Guangri-winding-machine-logo-2.webp","@id":"https:\/\/grwinding.com\/it\/transformer-winding-machine-operating-procedures\/#organizationLogo","width":2032,"height":446,"caption":"Guangri winding machine logo"},"image":{"@id":"https:\/\/grwinding.com\/it\/transformer-winding-machine-operating-procedures\/#organizationLogo"},"sameAs":["https:\/\/www.facebook.com\/profile.php?id=100067574001915","https:\/\/www.instagram.com\/guangri_electronic_machinery\/","https:\/\/www.tiktok.com\/@guangrielectronic?lang=zh-Hans","https:\/\/www.youtube.com\/channel\/UCgjvOcsgZW6E_RB6H87pkrA","https:\/\/www.linkedin.com\/company\/89337373\/admin\/"]},{"@type":"Person","@id":"https:\/\/grwinding.com\/it\/author\/judy\/#author","url":"https:\/\/grwinding.com\/it\/author\/judy\/","name":"\u6731\u8fea","image":{"@type":"ImageObject","@id":"https:\/\/grwinding.com\/it\/transformer-winding-machine-operating-procedures\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/6df3edc77d960c3f27b8a93aa8be58836a8f13999fceccfb2ad4039d559a72e0?s=96&d=mm&r=g","width":96,"height":96,"caption":"\u6731\u8fea"}},{"@type":"WebPage","@id":"https:\/\/grwinding.com\/it\/transformer-winding-machine-operating-procedures\/#webpage","url":"https:\/\/grwinding.com\/it\/transformer-winding-machine-operating-procedures\/","name":"Transformer Winding Machine: Operating Procedures 2026","description":"Explore toroidal transformer winding machine setup, pre-operation checks, idle-run verification, wire loading, and basic winding procedures.","inLanguage":"it-IT","isPartOf":{"@id":"https:\/\/grwinding.com\/it\/#website"},"breadcrumb":{"@id":"https:\/\/grwinding.com\/it\/transformer-winding-machine-operating-procedures\/#breadcrumblist"},"author":{"@id":"https:\/\/grwinding.com\/it\/author\/judy\/#author"},"creator":{"@id":"https:\/\/grwinding.com\/it\/author\/judy\/#author"},"datePublished":"2026-11-16T08:18:59+00:00","dateModified":"2026-11-17T08:42:13+00:00"},{"@type":"WebSite","@id":"https:\/\/grwinding.com\/it\/#website","url":"https:\/\/grwinding.com\/it\/","name":"GuangRi","inLanguage":"it-IT","publisher":{"@id":"https:\/\/grwinding.com\/it\/#organization"}}]},"og:locale":"it_IT","og:site_name":"GuangRi -","og:type":"article","og:title":"Transformer Winding Machine: Operating Procedures 2026","og:description":"Explore toroidal transformer winding machine setup, pre-operation checks, idle-run verification, wire loading, and basic winding procedures.","og:url":"https:\/\/grwinding.com\/it\/transformer-winding-machine-operating-procedures\/","og:image":"https:\/\/grwinding.com\/wp-content\/uploads\/2023\/11\/guangri-winding-machine-logo.webp","og:image:secure_url":"https:\/\/grwinding.com\/wp-content\/uploads\/2023\/11\/guangri-winding-machine-logo.webp","og:image:width":2252,"og:image:height":449,"article:published_time":"2026-11-16T08:18:59+00:00","article:modified_time":"2026-11-17T08:42:13+00:00","article:publisher":"https:\/\/www.facebook.com\/profile.php?id=100067574001915","twitter:card":"summary_large_image","twitter:title":"Transformer Winding Machine: Operating Procedures 2026","twitter:description":"Explore toroidal transformer winding machine setup, pre-operation checks, idle-run verification, wire loading, and basic winding procedures.","twitter:image":"https:\/\/grwinding.com\/wp-content\/uploads\/2023\/11\/guangri-winding-machine-logo.webp"},"aioseo_meta_data":{"post_id":"9456","title":null,"description":null,"keywords":null,"keyphrases":{"focus":{"keyphrase":"transformer winding machine","score":0,"analysis":[]},"additional":[{"keyphrase":"Toroidal Transformer Winding Machine","score":0},{"keyphrase":"Toroidal Winding Machine Operation","score":0}]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"seo_analyzer_scan_date":"2026-11-17 08:42:59","breadcrumb_settings":null,"limit_modified_date":false,"reviewed_by":null,"open_ai":null,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":{"subject":"","preview":"","content":""},"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"created":"2026-11-14 06:54:42","updated":"2026-11-17 08:43:07","focus_keyword":"transformer winding machine","additional_keywords":[{"word":"Toroidal Transformer Winding Machine","score":91,"items":{"introductionKeyword":{"score":9},"keyphraseLength":{"score":9},"keyphraseDensity":{"score":4},"functionWordsInKeyphrase":{"score":9},"textCompetingLinks":{"score":9},"imageKeyphrase":{"score":9}}},{"word":"Toroidal Winding Machine Operation","score":80,"items":{"introductionKeyword":{"score":3},"keyphraseLength":{"score":9},"keyphraseDensity":{"score":4},"functionWordsInKeyphrase":{"score":9},"textCompetingLinks":{"score":9},"imageKeyphrase":{"score":9}}}],"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/grwinding.com\/it\/\" title=\"Guangri\">Guangri<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u2013<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/grwinding.com\/it\/category\/uncategorized\/\" title=\"Uncategorized\">Uncategorized<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">\u2013<\/span><span class=\"aioseo-breadcrumb\">\n\tTransformer Winding Machine: Operating Procedures\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Guangri","link":"https:\/\/grwinding.com\/it\/"},{"label":"Uncategorized","link":"https:\/\/grwinding.com\/it\/category\/uncategorized\/"},{"label":"Transformer Winding Machine: Operating Procedures","link":"https:\/\/grwinding.com\/it\/transformer-winding-machine-operating-procedures\/"}],"_links":{"self":[{"href":"https:\/\/grwinding.com\/it\/wp-json\/wp\/v2\/posts\/9456","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/grwinding.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/grwinding.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/grwinding.com\/it\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/grwinding.com\/it\/wp-json\/wp\/v2\/comments?post=9456"}],"version-history":[{"count":24,"href":"https:\/\/grwinding.com\/it\/wp-json\/wp\/v2\/posts\/9456\/revisions"}],"predecessor-version":[{"id":9485,"href":"https:\/\/grwinding.com\/it\/wp-json\/wp\/v2\/posts\/9456\/revisions\/9485"}],"wp:attachment":[{"href":"https:\/\/grwinding.com\/it\/wp-json\/wp\/v2\/media?parent=9456"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/grwinding.com\/it\/wp-json\/wp\/v2\/categories?post=9456"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/grwinding.com\/it\/wp-json\/wp\/v2\/tags?post=9456"}],"curies":[{"name":"scrivere","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}